OTDR - Optical Time Domain Reflectometer

electrical theory and electrical fundementals for all electrical related people . students , engineers, electrician #electricaltheorems,electrical,

The architecture and the operation of the OTDR system
The OTDR is the most important investigation tool for optical fibres, which is applicable for the measurement of fibre loss, connector loss and for the determination of the exact place and the value of cabel discontinuities. By means of very short pulses it is also possible to measure the modal dispersion of multimodal fibres. The structure of a typical OTDR equipment is shown below:
The principal of the OTDR analyzer is the following: a short light pulse is transmitted into the fibre under test and the time of the incidence and the amplitude of the reflected pulses are measured. The commonly used pulse width ranges from nanosecs to microsecs, the power of the pulse can exceed 10 mW. The repetition frequency depends on the fibre length, typically is between 1 and 20 kHz, naturally it is smaller for longer fibres. The division by 2 at the inputs of oscilloscope is needed since both the vertical (loss) and the horizontal (length) scales correspond to the one-way length.

The components of the fibre loss and their importance in the OTDR measurements

There are three reasons for the fibre loss:

• absorption

• radiation loss

• Rayleigh scattering

The absorption creates 10-20% of the fibre loss. It mainly originates from the OH- ions inside the fibre material (impurities). With modern technologies the number of these contaminants, so the loss can be kept at relatively low level. The fibre loss increases dinamically for wavelengths above 1700 nm, thus this is the lowest frequency for optical telecommunications. In practice the 1300 and 1550 nm wavelengths are used as the insertion loss shows minimal values at these wavelengths. Naturally, absorption does not induce reflection, so if this would be the only physical phenomena, the fibre loss could be measured by the means of OTDR only with a well known, calibrated termination

In practice, the fibre continuously radiates backwards due to the Rayleigh scattering, which will be described later, so the absorption loss is measured together with the other losses.
Radiation loss occurs when the geometrical parameters of the fibre abruptly change, or a mechanical tension is present in the fibre material due to fabrication failure or mechanical impact. Considering appropriate fabrication technologies and fibre jacket, the radiation loss can be neglected and, like absorption, it does not create reflections, so from the OTDR measurements point of view it can handle as absorption losses. A high level discontinuity originated by e.g. strong folding, can be shown by OTDR as it produces high loss.
During OTDR measurements the most important loss is the one caused by Rayleigh scattering. It generates the 80-90% of the total loss. The scattering is induced by the microscopic inhomogenity of the refractive index of the fibre. These inhomogenities cause diffraction, so a certain part of the light energy is radiated isotropically. The level of the diffrection reaches its maximum when the wavelength is in the same range as the dimensions of the microscopic inhomogenities. Thus the level of the scattering decreases when the wavelength is increased. Among others this is the reason for using the 1300 and the 1550 nm ranges instead of the 850 nm. A certain part of the diffracted light propagates backwards in the fibre which is, when measured, carries important information. In the following, we calculate the ratio of the diffracted and the backward propagating light.

Friday, 29 May 2015

itemprop='blogPost' itemscope='itemscope' itemtype='http://schema.org/BlogPosting'>

Electric panel

electrical theory and electrical fundementals for all electrical related people . students , engineers, electrician #electricaltheorems,electrical,


Friday, 27 February 2015

itemprop='blogPost' itemscope='itemscope' itemtype='http://schema.org/BlogPosting'>

HOW TO SELECT BUSBAR

electrical theory and electrical fundementals for all electrical related people . students , engineers, electrician #electricaltheorems,electrical,

How to select busbar for electrical systems 

Busbar Voltage Drop

The Busbar voltage drop is the expected resistive voltage drop on a busbar circuit, based on the             length and cross sectional area of the bar. There may be an additional voltage drop due to the inductance of the bar. This can become particularly important at high frequencies and high currents. Where there are a number of bars in parallel, assume the bar width is the actual width multiplied by the number of bars in parallel. i.e. 5 bars of 50 x 6 mm in parallel would give the same resistive voltage drop as a single bar of 50 x 30mm.
To calculate the resistive voltage drop of a length of busbar, enter in the width, length and thickness of the bar. Select the units as either metric or imperial. and the current passing through the bar. The circuit configuration also needs to be specified. "Single bar" refers to the voltage drop along a single length of bar, while "Single Phase" refers to the voltage drop of two equal lengths of bar, one in the active circuit and one in the neutral circuit. "Three Phase" calculates the voltage drop between the supply and a three phase load where three equal bars are used for the three phase circuits. Enter the ambient temperature around the bar as Celsius or Fahrenheit and the program will check the suitability of the bar for that current. The program displays the resistive voltage drop for both an aluminium bar of these dimensions and a copper bar of these dimensions

Busbar Power Dissipation

The total  Power Dissipated in the busbar is dependent on the resistance of the bar, it's length and the square of the RMS current flowing through it The power dissipated in the busbar is proportional to the square of the current, so if the busbar has a cyclic load, the current should be the RMS current rather than the average. If the maximum current flows for a considerable period of time, this must be used as the current to determine the maximum busbar temperature, but the power dissipation is based on the square root of the maximum current squared times the period for which it flows plus the lower current squared times the period it flows all divided by the square root of the total time. For example, a busbar carries a current of 600 Amps for thirty seconds, then a current of 100 amps for 3000 seconds, then zero current for 3000 seconds. The power dissipation is based on an RMS current of sqrt(600x600x30 + 100x100x3000 + 0 x 3000)/sqrt(30 + 3000 + 3000) = 82.25 Amps.
To calculate the Power Dissipation of a busbar, enter in the width, length and thickness of the bar, and the RMS Current passing through it. Select the units as either metric or imperial. The program displays the Power Dissipated in both an aluminium bar of these dimensions and a copper bar of these dimensions. Enter the ambient temperaturearound the bar in either Celsius or Fahrenheit and the program will check the suitability of the bar for this application.

Busbar Ratings 

Busbar ratings are based on the expected surface temperature rise of the busbar. This is a function of the thermal resistance of the busbar and the power it dissipates. The thermal resistance of the busbar is a function of the surface area of the busbar, the orientation of the busbar, the material from which it is made, and the movement of air around it. The power dissipated by the bus bar is dependent on the square of the current passing through it, its length, and the material from which it is made. Optimal ratings are achieved when the bar runs horizontally with the face of the bar in the vertical plane. i.e. the bar is on its edge. There must be free air circulation around all of the bar in order to afford the maximum cooling to its surface. Restricted airflow around the bar will increase the surface temperature of the bar. If the bar is installed on its side, (largest area to the top) it will run at an elevated temperature and may need considerable derating. The actual derating required depends on the shape of the bar. Busbars with a high ratio between the width and the thickness, are more sensitive to their orientation than busbars that have an almost square cross section. Vertical busbars will run much hotter at the top of the bar than at the bottom, and should be
derated in order to reduce the maximum temperature within allowable limits. Maximum Busbar ratings are not the temperature at which the busbar is expected to fail, rather it is the maximum temperature at which it is considered safe to operate the busbar due to other factors such as the temperature rating of insulation materials which may be in contact with, or close to, the busbar. Busbars which are sleeved in an insulation material such as a heatshrink material, may need to be derated because of the potential aging and premature failure of the insulation material.
The Maximum Current rating of Aluminium Busbars is based on a maximum surface temperature of 90 degrees C (or a 60 degree C temperature rise at an ambient temperature of 30 degrees C). If a lower maximum temperature rating is desired, increase the ambient temperature used for the calculations. i.e. If the actual ambient temperature is 40 degrees C and the desired maximum bar temperature is 80 degrees C, then set the ambient temperature in the calculations to 40 + (90-80) = 50 degrees C. The  Maximum Current rating of Copper Busbars is based on a maximum surface temperature of 105 degrees C (or a 75 degree C temperature rise at an ambient temperature of 30 degrees C).
The  Busbar Width is the distance across the widest side of the busbar, edge to edge.
The Busbar Thickness is the thickness of the material from which the Busbar is fabricated. If the busbar is manufactured from a laminated material, then this is the overall thickness of the bar rather than the thickness of the individual elements. The  Busbar Length is the total length of busbar used.
The  Busbar Current is the maximum continuous current flowing through the busbar. The power dissipated in the busbar is proportional to the square of the current, so if the busbar has a cyclic load, the current should be the RMS current rather than the average. If the maximum current flows for a considerable period of time, this must be used as the current to determine the maximum busbar temperature, but the power dissipation is based on the square root of the maximum current squared times the period for which it flows plus the lower current squared times the period it flows all divided by the square root of the total time. For example, a busbar carries a current of 600 Amps for thirty seconds, then a current of 100 amps for 3000 seconds, then zero current for 3000 seconds. The power dissipation is based on an RMS current of sqrt(600x600x30 + 100x100x3000 + 0 x 3000)/ssqrt30 + 3000 + 3000) = 82.25 Amps.
The  Ambient Temperature is the temperature of the air in contact with the busbar. If the air is in an enclosed space, then the power dissipated by the busbar will cause an increase in the ambient temperature within the enclosure.
To calculate the rating of a busbar, enter in the width and thickness of the bar, and the ambient temperature around the bar. Select the units as either metric or imperial, and the temperature as Celsius or Fahrenheit. The program displays both the current rating of an aluminium bar of these dimensions and a copper bar of these dimensions.

Monday, 9 February 2015

itemprop='blogPost' itemscope='itemscope' itemtype='http://schema.org/BlogPosting'>

SILICON CONTROLLED RECTIFIER (SCR)

electrical theory and electrical fundementals for all electrical related people . students , engineers, electrician #electricaltheorems,electrical,

The Silicon Controlled Rectifier is the most popular of the thyristor family of four layer regenerative devices. It is normally turned on by the application of a gate pulse when a forward bias voltage is present at the main terminals. However, being regenerative or 'latching', it cannot be turned off via the gate terminals specially at the extremely high amplification factor of the gate. There are two main types of SCR's
Converter grade or Phase Control thyristors These devices are the work horses of the Power Electronics. They are turned off by natural (line) commutation and are reverse biased at least for a few milliseconds subsequent to a conduction period. No fast switching feature is desired of these devices. They are available at voltage ratings in excess of 5 KV starting from about 50 V and current ratings of about 5 KA. The largest converters for HVDC transmission are built with series-parallel combination of these devices. Conduction voltages are device voltage rating dependent and range between 1.5 V (600V) to about 3.0 V (+5 KV). These devices are unsuitable for any 'forced-commutated' circuit requiring unwieldy large commutation components.
The dynamic di/dt and dv/dt capabilities of the SCR have vastly improved over the years borrowing emitter shorting and other techniques adopted for the faster variety. The requirement for hard gate drives and di/dt limting inductors have been eliminated in the process.

Inverter grade thyristors: 

Turn-off times of these thyristors range from about 5 to 50 μsecs when hard switched. They are thus called fast or 'inverter grade' SCR's. The SCR's are mainly used in circuits that are operated on DC supplies and no alternating voltage is available to turn them off. Commutation networks have to be added to the basic converter only to turn-off the SCR's. The efficiency, size and weight of these networks are directly related to the turn-off time, tq of the SCR. The commutation circuits utilised resonant networks or charged capacitors. Quite a few commutation networks were designed and some like the McMurray-Bedford became widely accepted
Asymmetrical, light-activated, reverse conducting SCR's Quite a few varieties of the basic SCR have been proposed for specific applications. The Asymmetrical thyristor is convenient when reactive powers are involved and the light activated SCR assists in paralleling or series operation.